**Catalogue Models & Dimensions**
| Cat. Ref. | PCD (mm) | L1 (mm) | L (mm) | H (mm) | |———–|———-|———|——–|——–| | FCSH225 | 310 | 1000 | 800 | 75 | | FCSH300 | 395 | 1000 | 800 | 75 | | FCSH400 | 495 | 1200 | 1000 | 75 | | FCSH450 | 585 | 1200 | 1000 | 100 | | FCSH600 | 710 | 1400 | 1200 | 100 |
**Features & Installation Guidance**
– Supplied with full-threaded jacking rods and U-bolts for precise leveling and adjustment during installation.
– The frame is fixed to the foundation using foundation bolts passing through the base plate or U-bolt arrangement
– After alignment, grouting is applied to distribute load and lock the frame in position.
– The base frame must interface properly with the vertical tube base fitting and the rest of the support frame
– The design must consider differential expansion, load distribution, and lateral stability from the upper structure