spherical vessels1

2

Nominal Capacity (Ltrs.)Maximum Pressure (Bar)
 51
 50.8
 200.7
 500.5
 1000.4
 2000.3
 3000.2
 5000.1

Get in Touch

Our Sales Executive will Assist you soon.

Get Enquire

spherical vessels2
Nominal Capacity(Ltrs.)LLDDNTDN1BDN2PDN3S
 542542522350852512525504075
 10500500285801002512525504075
 205755753501001002512525504075
 50800800490150150402004075100100
 100900900600225150402004075100100
 20011001100750300250402004075100100
 30011751175860400250501755075100100
 500140014001000450250502005075150165
            

Get in Touch

Our Sales Executive will Assist you soon.

Get Enquire

3 Single Neck Spherical Vessel

spherical vessels3
Cat.Ref.Nominal CapacityLDN
 VSA55 L30050
 VSA1010 L37580
 VSA2020 L450100
 VSA5050 L600150
 VSA100100 L700225
 VSA200200 L900300
 VSA300300 L1000400
 VSA500500 L1200450

4 Three Neck Bottom Outlet Spherical Vessels

spherical vessels4
Cat.Ref.Nominal CapacityLDNDN1DN2
 VSM55 L450502525
 VSM1010 L500802525
 VSM20*20 L5751002525
 VSM50*50 L8001504040
 VSM100100 L9002254040
 VSM200200 L11003004040
 VSM300300 L11754005050
 VSM500500 L14004505050

5.FOUR NECK BOTTOM OUTLET SPHERICAL VESSELS

spherical vessels5
Cat.Ref.Nominal CapacityLDNDN1DN2DN3
 VSPL55 L42550252540
 VSPL1010 L50080252540
 VSPL2020 L575100252540
 VSPL5050 L8001504040100
 VSPL100100 L9002254040100
 VSPL200200 L11003004040100
 VSPL300300 L11754005050100
 VSPL500500 L14004505050150

FIVE NECK BOTTOM OUTLET SPHERICAL VESSEL

spherical vessels7
Cat.Ref.Nominal CapacityLDNDN1DN2DN3
 VS 55 L42550252540
 VS 1010 L50080252540
 VS 2020 L575100252540
 VS 50*50 L8001504040100
 VS 100*100 L9002254040100
 VS 200*200 L11003004040100
 VS 300300 L11754005050100
 VS 500500 L14004505050100

SPHERICAL VESSELS WITH NOZZLE AT 90°

spherical vessels8

These vessels are used in Circulatory Boiler System and are to be supported on a vessel holder. More nozzles can be provided on the equator on request for special requirements.

Cat.Ref.Nominal CapacityLDNDN1DN2DN3
 VSD55 L42550252550
 VSD1010 L50080252550
 VSD2020 L575100252550
 VSD5050 L800150404080
 VSD100100 L900225404080
 VSD200200 L11003004040150
 VSD300300 L11754005050150
 VSD500500 L14004505050150

SPHERICAL CYCLONES

spherical vessels9

Cyclones can be used for the separation of droplets and solids from gases and vapours. Cyclones are to be supported on a vessel holder. A dip pipe should be used on the top neck.

Cat. Ref.Nominal CapacityLDNDN1DN2DN3
 VSCY55 L42550252540
 VSCY1010 L50080252540
 VSCY2020 L575100252550
 VSCY5050 L800150404050

ADDITION VESSELS

These vessels are provided with a short bottom outlet. These should be supported on a vessel holder/ holding ring.

spherical vessels10
Cat.Ref.Nominal CapacityLDNDN1
 VA5*5 L37536050
 VA10*10 L4358025
 VA20*20 L51010025
 VA5050 L67515040
 VA100100 L77522540
 VA200200 L97530040
 VA300300 L107540050
 VA500500 L140045050

SPHERICAL VESSELS WITH WIDE BOTTOM OUTLET

These vessels are generally used to fit immersion exchangers in the bottom. Special heating mantle or bath should be used if used with.

spherical vessels11
Cat.Ref.Nominal CapacityLDNDN1DN2DN3
 VSR5050 L75015015040100
 VSR100100 L85022515040100
 VSR200200 L105030015040100
 VSE5050 L80015022540100
 VSE100100 L90022522540100
 VSE200200 L110030022540100

VESSELS WITH BOTTOM OUTLET VALVE SEAT

spherical vessels14

To fit a bottom outlet valve (BAL type) all spherical and cylindrical vessels can be supplied with valve seat in bottom outlet. For this, Add a suffix “/B” to the catalogue reference of a vessel, for e.g. ‘VSL50’ should be mentioned as ‘VSL50/B’.

NOTES ON USE OF SPHERICAL VESSELS :

1. Generally, the centre nozzle, referred as DN in all types of vessels, is used for either stirrer fixing or, if stirrer is not fixed, for vapour outlet.

2. The bottom outlet, referred as DN1 in all types, is used for drain. However, in type VSR & VSE, it is also used for fixing immersion heat exchanger.

3. The small side nozzles, referred as DN2 in all types, are used (a) to fix thermometer pocket or

(b) to fix dip pipe for liquid inlet or,
(c) to fix sparger for gas purging or,
(d) to fix vacuum control or vent valve or,
(e) for solid addition.

4. The bigger side nozzle, referred as Dn3, is used for vapour outlet where stirrer is fixed on centre neck. It can also be used for cleaning in case centre neck is used for vapour outlet.

5. Vessels having long bottom outlet, viz VSM, VSPL, VSL, VS etc, can be supported in a heating mantle of heating bath. However, vessels having short bottom outlet, viz VSD, VSCY, VR, VA etc. are to be supported on a vessel holder only. In case of vessels upto 20L size, vessel holding rings can be used instead of vessel holder.

*marked items are available fast.